Photoelectric sensor in compact M18 housing
E3F1
• M18 size Photoelectric sensor with best value at competitive price
• Bright visible red LED enabling easy alignment
• Compact and robust housing for easy integration into machines
• Reliable operation in all industrial environments
Ordering Information
Sensors [Refer to Dimensions on page 5.]
Sensor type
Red light
Sensing distance
Through-beam
15 m
Retro-reflective*2
0.1 to 3 m
with E39-R1S
Diffuse-reflective
100 mm
300 mm
*1
*2
Model
Connection method
NPN output
PNP output
*1
E3F1-TP11 2M*1
pre-wired
E3F1-TN11 2M
M12 connector
E3F1-TN21*1
E3F1-TP21*1
pre-wired
E3F1-RN11 2M
E3F1-RP11 2M
M12 connector
E3F1-RN21
E3F1-RP21
pre-wired
M12 connector
pre-wired
M12 connector
E3F1-DN11 2M
E3F1-DN21
E3F1-DN12 2M
E3F1-DN22
E3F1-DP11 2M
E3F1-DP21
E3F1-DP12 2M
E3F1-DP22
Includes the emitter and receiver.
The Reflector is sold separately.
Reflectors [Refer to Dimensions on page 6.]
Reflectors required for Retro-reflective Sensors: A Reflector is not provided with the Sensor. Be sure to order a Reflector separately.
Sensor
E3F1-R@
Sensing distance
Appearance
0.1 to 3 m
Model
E39-R1S
Remarks
Quantity
1
for E3F1-R@
Mounting brackets [Refer to Dimensions on page 6.]
A Mounting Bracket is not enclosed with the Sensor. Order a Mounting Bracket separately if required.
Sensor
Appearance
Model (Material)
Quantity
Remarks
E39-L183 (SUS304)
1
Mounting bracket
E39-L182 (POM)
1
Flush mounting bracket
all types
1
E3F1
Sensor I/O connectors
Models for Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.
Sensor
Size
Cable
Appearance
Cable type
2m
Straight
5m
M12 connector types
M12
Standard
Model
XS2F-M12PVC4S2M-EU
XS2F-M12PVC4S5M-EU
4-wire
Angle
2m
XS2F-M12PVC4A2M-EU
5m
XS2F-M12PVC4A5M-EU
Specifications
Sensing method
Model NPN
Pre-wired
output
M12 Connector
Pre-wired
PNP
output
Item
M12 Connector
Through-beam
E3F1-TN11 2M
E3F1-TN21
E3F1-TP11 2M
E3F1-TP21
Retro-reflective
E3F1-RN11 2M
E3F1-RN21
E3F1-RP11 2M
E3F1-RP21
Sensing distance
15 m
0.1 to 3 m
(with E39-R1S)
Spot diameter (typical)
Directional angle
Light source (wavelength)
Power supply voltage
Current consumption
Control output
Operation mode
Indicator
Protection circuits
Response time
Sensitivity adjustment
Ambient temperature range
Ambient humidity range
Degree of protection
Weight
(packed
state/only
sensor)
Material
Pre-wired cable (2M)
Connector
Case
Lens and Display
Adjuster
Nut
Accessories
2
—
—
Diffuse-reflective
E3F1-DN11 2M
E3F1-DN12 2M
E3F1-DN21
E3F1-DN22
E3F1-DP11 2M
E3F1-DP12 2M
E3F1-DP21
E3F1-DP22
100 mm
300 mm
(white paper:
(white paper:
300 300 mm)
300 300 mm)
40 45 mm
40 50 mm
Sensing distance
Sensing distance
of 100 mm
of 300 mm
—
—
2° min.
2° min.
Red LED (624 nm)
10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
40 mA max.
(Emitter 25 mA max.
25 mA max.
Receiver 15 mA max.)
NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max.
Light-ON/Dark-ON selectable by wiring
Operation indicator (orange)
Stability indicator (green)
Power indicator (green): only Emitter of Through-beam
Reversed power supply polarity protection, Output short-circuit protection and Reversed output polarity protection
0.5 ms
One-turn adjuster
Operating: -25 to 55°C/ Storage: -30 to 70°C (with no icing or condensation)
Operating: 35 to 85%RH/ Storage: 35 to 95%RH (with no condensation)
IEC: IP66
Approx. 110 g/
Approx. 50 g,
Approx. 60 g/ Approx. 50 g
respectively
Approx. 30 g/
Approx. 10 g,
Approx. 20 g/ Approx. 10 g
respectively
ABS
PMMA
POM
ABS
Instruction sheet
Instruction sheet
M18 nuts (4 pcs)
M18 nuts (2 pcs)
E3F1
Output circuit diagram
PNP Output
Operation
mode
Model
Light-ON
Operation
selector
Timing charts
Light incident
Light interrupted
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Operate
Load
(e.g., relay)
Reset
Connect the
pink wire
(Pin(2)) to the
brown (Pin(1))
Output circuit
Through-beam Receivers, Retro-reflective Models,
Diffuse-reflective Models
(Between blue
and black leads)
E3F1-TP@
E3F1-RP@
E3F1-DP@
Dark-ON
Light incident
Light interrupted
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Load
Operate
(e.g., relay)
Reset
(Between blue
and black leads)
Stability
indicator
(Green)
Operation
indicator
(Orange)
1
Light-ON
100 mA max.
(Control output)
Black
Photoelectric
Sensor
Main
Circuit
Connect the
pink wire
(Pin(2)) to the
blue (Pin(3))
or open the
pink wire
(Pin(2))
10 to 30 VDC
Brown
4
Blue
Load
(Relay)
3
2
0V
Pink
Dark-ON
Through-beam Emitter
Brown
Power
indicator
(green)
1
Photoelectric
Sensor
Main
Circuit
10 to 30 VDC
Blue
3
NPN Output
Operation
mode
Model
Light-ON
E3F1-TN@
E3F1-RN@
E3F1-DN@
Dark-ON
Operation
selector
Timing charts
Light incident
Light interrupted
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Operate
Load
(e.g., relay)
Reset
(Between brown
and black leads)
Output circuit
Through-beam Receivers, Retro-reflective Models,
Connect the
Diffuse-reflective Models
pink wire
(Pin(2)) to the
brown (Pin(1))
10 to 30 VDC
Brown
Stability
Operation
1
or open the
indicator
indicator
Light-ON
Load
(Green)
(Orange)
pink wire
(Relay)
Black
(Pin(2))
Photo100 mA max.
4
electric
Sensor
Main
Circuit
Light incident
Light interrupted
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Load
Operate
(e.g., relay)
Reset
(Between brown
and black leads)
(Control output)
3
Connect the
pink wire
(Pin(2)) to the
blue (Pin(3))
2
Blue
0V
Pink
Dark-ON
Through-beam Emitter
Power
indicator
(green)
Brown
1
Photoelectric
Sensor
Main
Circuit
10 to 30 VDC
Blue
3
Connector Pin Arrangement
Connectors (Sensor I/O connectors)
M12 Connector Pin Arrangement
M12 4-wire Connectors
1
2
Pin No.
4
2
3
1
3
4
Classification
DC
Wire color
Brown
White
Blue
Black
1
2
3
4
Wire color
Connector pin No.
Application
Brown
➀
➁
➂
➃
Power supply (+V)
White
Blue
Black
L/on · D/on selectable
Power supply (0 V)
Output
3
E3F1
Nomenclature
Straight
with an adjuster:
E3F1-T@-D
E3F1-R@
E3F1-D@
without an adjuster:
E3F1-T@-L *
Sensitivity adjuster
Stability indicator
(Green)
Operation indicator
(Orange)
* The Emitter has two Power indicators (Green) instead of the Stability indicator (Green) and the Operation indicator (Orange).
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for directly or
indirectly ensuring safety of persons. Do not use it
for such a purpose.
CAUTION
Never use the product with an AC power supply.
Do not use the product with voltage in excess of the
rated voltage.
Do not use the product with incorrect wiring.
Otherwise, explosion, fire, malfunction may result.
Precautions for Safe Use
Be sure to follow the safety precautions below for added safety.
1. Do not use the sensor under the environment with explosive,
flammable or corrosive gas.
2. Do not use the sensor under the oil or chemical environment.
3. Do not use the sensor in the water, rain or outdoors.
4. Do not use the sensor in the environment where humidity is high
and condensation may occur.
5. Do not use the sensor under the environment under the other
conditions in excess of rated.
6. Do not use the sensor in place that is exposed by direct sunlight.
7. Do not use the sensor in place where the sensor may receive
direct vibration or shock.
8. Do not use the thinner, alcohol, or other organic solvents.
9. Never disassemble, repair nor tamper with the sensor.
10.Please process it as industrial waste.
Precautions for Correct Use
1. Laying Sensor wiring in the same conduit or duct as high-voltage
wires or power lines may result in malfunction or damage due to
conduit or use shielded cable.
2. Do not pull on the cable with excessive force.
3. If a commercial switching regulator is used, ground the FG (frame
ground) terminal.
4. The sensor will be available 100 ms after the power supply is tuned
ON. Start to use the sensor 100 ms or more after turning ON the
power supply. If the load and the sensor are connected to separate
power supplies, be sure to turn ON the sensor first.
5. Output pulses may be generated even when the power supply is
OFF. Therefore, it is recommended to first turn OFF the power
supply for the load or the load line.
6. The sensor must be mounted using the provided nuts. The proper
tightening torque range is between 0.4 and 0.5 N·m.
4
E3F1
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Sensors
Pre-wired Models
E3F1-T@
E3F1-R@
E3F1-D@
Front view
Left side view
15
15
Receiver
Emitter
Optical axis
M12 Connector Models
E3F1-T@
E3F1-R@
E3F1-D@
Operation indicator (orenge)
2
7 dia.
M18 × 30.5 P=1
Optical axis
Suitable models
E3F1-R@11
E3F1-D@1@
23
30.5
* Suitable models
E3F1-T@11-D
E3F1-R@12
E3F1-D@1@
Right side view
Sensitivity adjuster *
45
Left side view
Left side view
15
15
Receiver
34.5
2
7 dia.
M18 × 30.5 P=1
Operation indicator (orenge)
Sensitivity indicator (green)
2
Mounting Holes
18.5+0.5
0 dia.
1
16.6 dia.
7
Emitter
Suitable models
E3F1-T@21
18.5+0.5
0 dia.
Vinyl insurated round cord 4 dia. 4 cores
(conductor cross sectional area:0.128 mm2 (AWG26)
/insulation outside diameter:0.85 dia.)
standard length 2 m
Front view
Optical axis
Mounting Holes
Sensitivity indicator (green)
16.6 dia.
7
Suitable models
E3F1-T@11
Sensitivity adjuster *
41
34.5
Left side view
Optical axis
Suitable models
E3F1-R@21
E3F1-D@2@
23
30.5
M12 × 4 P=1
* Suitable models
E3F1-T@21-D
E3F1-R@22
E3F1-D@2@
3
4
Terminal No.
Specification
1
+V
2
L/on · D/on selectable
3
0V
4
Output
Attached nut
24 dia.
8
Three, 22
M18 × 7.5 P=1
5
E3F1
Accessories (Order Separately)
Reflectors
E39-R1S
40.3
34
Two, 3.5 dia.
7.5
7
59.9
52
8
2.7
1.6
Mounting brackets
E39-L183
Mounting brackets
E39-L182
42
4.3
Two, R15
16
Two, 30°
Two, 4.3
37
14.5 12.5
23
1.5
(R16.5)
27 dia.
90°
18.2 dia.
15.1
36.5
20
6
16.7 dia.
E3F1
7
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
Cat. No. E94E-EN-01
In the interest of product improvement, specifications are subject to change without notice.
OMRON EUROPE B.V.
Wegalaan 67-69,
NL-2132 JD, Hoofddorp,
The Netherlands
Phone: +31 23 568 13 00
Fax: +31 23 568 13 88
www.industrial.omron.eu